Model No. | Product specifications | Area of exclusive use | Electricity consumption | Notes |
---|---|---|---|---|
DW SC – Series | ||||
DW22.5SC | 22.5m x Ø7.5mm | 3.3㎡(1.0py) | 900W/h | 40W/m Steel Wire Reinforced. |
DW45SC | 45m x Ø7.5mm | 6.6㎡(3.0py) | 1800W/h | |
DW67.5SC | 67.5m x Ø7.5mm | 9.9㎡(3.0py) | 2700W/h | |
DW90SC | 90m x Ø7.5mm | 13.2㎡(4.0py) | 3600W/h | |
DW112.5SC | 112.5m x Ø7.5mm | 16.5㎡(5.0py) | 4500W/h | |
DW SA – Series | ||||
DW22.5SA | 22.5m x Ø7.5mm | 3.3㎡(1.0py) | 900W/h | 40W/m SUS Braided. |
DW45SA | 45m x Ø7.5mm | 6.6㎡(3.0py) | 1800W/h | |
DW67.5SA | 67.5m x Ø7.5mm | 9.9㎡(3.0py) | 2700W/h | |
DW90SA | 90m x Ø7.5mm | 13.2㎡(4.0py) | 3600W/h | |
DW112.5SA | 112.5m x Ø7.5mm | 16.5㎡(5.0py) | 4500W/h |
Model No. | Product specifications | Area of exclusive use | Electricity consumption | Notes |
---|---|---|---|---|
DW SMC – Series (1core) | ||||
DW22.5SMC | 22.5m x Ø6.5mm | 3.3㎡(1.0py) | 900W/h | 40W/m |
DW45SMC | 45m x Ø6.5mm | 6.6㎡(3.0py) | 1800W/h | |
DW67.5SMC | 67.5m x Ø6.5mm | 9.9㎡(3.0py) | 2700W/h | |
DW90SMC | 90m x Ø6.5mm | 13.2㎡(4.0py) | 3600W/h | |
DW112.5SMC | 112.5m x Ø6.5mm | 16.5㎡(5.0py) | 4500W/h | |
DW SML – Series (2core) | ||||
DW22.5SML | 22.5m x Ø6.5mm | 3.3㎡(1.0py) | 900W/h | 40W/m |
DW45SML | 45m x Ø6.5mm | 6.6㎡(3.0py) | 1800W/h | |
DW67.5SML | 67.5m x Ø6.5mm | 9.9㎡(3.0py) | 2700W/h | |
DW90SML | 90m x Ø6.5mm | 13.2㎡(4.0py) | 3600W/h | |
DW112.5SML | 112.5m x Ø6.5mm | 16.5㎡(5.0py) | 4500W/h |
※ Product specifications (length), electricity consumption, and heating area can be customized
DW-SMC100S | |
---|---|
Constant Input Voltage Rating | 85V AC ~ 265V AC (Universal voltage) |
Output Rating | OUT Output : Zero Voltage Contact Point Method
SENSOR Output : DC 12V |
Drive | Electric |
Maximum Output | 3kW X 2 Circuits (Within 200V, 15A) |
Load Number Of Circuits | 2 Circuits |
Contact Points Used | 250V 20A (Resistive Load) X 2EA |
Temperature Display | -9℃~30℃ (Setting temperature),
-50℃~50℃ (displayed temperature) |
Degree Of Accuracy | ± 1℃ : condition of 1℃ change per 30 secs.(Delay Option 20secs.) |
Power Display | Display |
Operation Method | GND(1Mode),AIR(2Mode),GND+AIR(3Mode)
MANUAL(4Mode) – 4Types Of Modes |
Display Method | Exterior temperature, mode display, setting ground temperature,
present ground temperature, snow melting time display |
Method For Selecting Intensity | Long, Medium, Short – 3Type |
Operation Method Of
Channel Selection |
CH1, CH2 – 2Type |
Connection part (connection/TERMINAL BLOCK) |
Upper part – Motion sensor connection : 4PIN
Ground sensor connection : 2PIN per CH Power input connection : 2PIN Zero voltage output : 2PIN per CH Bottom Humidity sensor connection : 2PIN per CH Humidity heater connection : 2PIN per CH |
Weight | 390g |
Size | 157(W) X 151(H) X 57(D) (mm) |
Classification | Snow-removing equipment and calcium chloride | Automatic brine sprinkling method | Enerpia | |
---|---|---|---|---|
Cutting | Laying | |||
Construction Method | Sprinkles calcium chloride and uses snow-removing equipment | Installs snow-melting liquid storage tank and sprinkler nozzle facility to sprinkle the liquid on road surface | Conducts road cutting by certain gap on existing roads and installation sections to insert snow melting cable and perform finishing works | Wires and installs snow melting cable prior to road routing (prior to repavement and new pavement) |
Photo | ![]() |
![]() |
![]() |
![]() |
Advantages | Cleans up immediately | Excellent response to initial stage of heavy snowfall
Inexpensive construction cost and maintenance cost |
Excellent response to initial stage Automatic response to heavy snowfall Easy maintenance Eco-friendly |
Automatic response to heavy snowfall Clean construction surface Easy maintenance Eco-friendly |
Disadvantage | Immediate response is difficult when multiple sites are frozen at the same time. Issue of environmental pollution. Requires manpower for removing snow | Issue of environmental, vehicle corrosion, reduced road lifespan, requires consistent supplementation of snow-melting liquid | Exposure of cutting surface | Requires heating time |
Lowest average temperature (Jan. ~ Feb.) |
Snowfall (cm/hr) |
Road and street (W/m²) |
Bridge (W/m²) |
Stairs (W/m²) |
Port (W/m²) |
---|---|---|---|---|---|
-2℃ | 1.7cm | 170W | 200W | 170W | 250W |
-6℃ | 2cm | 200W | 250W | 200W | 300W |
-10℃ | 2.5cm | 250W | 300W | 250W | 350W |
-15℃ | 3cm | 300W | 350W | 300W | 400W |
-20℃ | 4cm | 350W | 400W | 350W | 450W |